| 1 to 10 of 1716: |
|
|
|||||
| HPLC(液相色谱)——苯肼硝基分析报告 08 Feb 2007: 使用LabTech HPLC COLUMN 250×4.6mm Kromasil C18色谱柱对苯肼硝基进行分析, 所得图谱显示该产品的可用性和准确性。 LabTech China |
|||||
| 毛细管电泳法直接分离测定水溶液中的Cd2+、Cu2+、Ni2+、Zn2+的研究 12 Mar 2004: 建立了毛细管电泳法测定水样中Cd2+、Cu2+、Ni2+、Zn2+金属离子的方法,研究了缓冲溶液种类、浓度、pH值;分离电压、有机添加剂对分离的影响,对分离条件进行了优化。在波长220nm,分离电压25KV,pH=4.30, 150mmol•L-1 HAc-NaAc乙醇(20%)缓冲溶液中,使Cd2+、Cu2+、Ni2+、Zn2+在5分钟内得到了较好的分离,且浓度与峰面积之间具有良好的线性关系。 Beijing Cailu Science Instruments Co., Ltd |
|||||
| Rapid His-Tag Purification of Recombinant Proteins Using Dionex ProPac IMAC Columns 01 Sep 2010: This application note demonstrates that the Dionex ProPac IMAC column can be used to successfully and rapidly purify His-Tagged recombinant proteins from cell-free extracts harvested from up to 1 L of E. coli fermentation cultures. Purification time may be reduced further through the application of a more concentrated sample with a smaller sample volume. Dionex Corporation |
|||||
| High-Throughput Melt Curve Analysis for Verification and Genotyping of SNPs in 4 Alaska Populations of Chum Salmon 25 Aug 2010: This application poster describes how the BioMark™ System and 96.96 Dynamic Array™ Integrated Fluidic Circuit (IFC) has been used by the University of Washington for verification and genotyping of SNP's in Alaskan populations of Chum Salmon. Fluidigm Corporation |
|||||
| In Vivo Monitoring of Fluorescently Labeled Cancer Cells 18 Aug 2010: This application poster demonstrates that both bioluminescence and fluorescence can be used to measure primary tumor growth and metastasis in vivo. Tumor progressions were monitored non-invasively and in real time using an enclosed imaging system containing a cooled CCD camera. Caliper Life Sciences |
|||||
| Measuring Molecular Mobility with Macro Fluorescence Imaging 18 Aug 2010: This application note examines GFP in live plants and observes systematic differences in areas non-invasively. This demonstrates that molecular mobility can be measured by macro imaging with steady state fluorescence anisotropy with the additional benefits of a large field-of-view which compliments both high throughput, in-vitro assay and in-vivo, non-invasive studies. UVP, LLC. |
|||||
| Trans-illumination – a Solution for Excitation of GFP Transfected Plants in Petri Dishes for In Vivo Imaging 18 Aug 2010: This application note shows that the excitation of GFP-transfected plants in Petri dishes filled with agar can be easily performed by Trans-illumination, with no reflection on the plastic material as it would happen with Epi-illumination. Background light intensities are in the range of 800-1000 RLU at 470 nm and 10% intensity setting of the transilluminator. BERTHOLD TECHNOLOGIES GmbH & Co. KG |
|||||
| Use of Antibodies In Small Animal Molecular Imaging 18 Aug 2010: In vivo imaging enables the natural course of a disease or experimental model to be monitored. This application note discusses the use of fluorescently labeled primary antibodies for looking at protein expression in vivo imaging. The use of antibodies allows researchers to quickly determine if the test antibody begins to target undesired organs such as the kidneys or livers. Carestream Molecular Imaging |
|||||
| Selecting Appropriate Technology for In-Process Monitoring and Control of Complex Particle and Droplet Systems 17 Aug 2010: This white papers explains the options available for real-time in-process monitoring and control of suspensions and emulsions, and provides direction for selecting the right technology for the work being performed. Mettler-Toledo AutoChem, Inc. |
| 转到第 |